As a leader in electromagnetic compatibility, EMC, regulatory compliance testing, Keystone Compliance assists electronic equipment manufacturers with EMC testing. Meeting the IEC, EN, and other international testing requirements can be challenging. Not only do we understand the challenges, but we help guide companies through the process.

Keystone Compliance’s accurate test reports are delivered quickly using our “four-eyes” approach. Our team takes pride in providing the peace of mind that all of your unintentional radiator testing needs will be met. Additionally, we are in constant communication throughout the entire test process. We tailor each test plan to individual customer needs minimizing unnecessary costs and over-testing. 

Request a quote to see why we are one of the fastest-growing MIL-STD-461 testing labs in the country. Ready to get started? We are. Contact us to achieve your EMC compliance testing needs. 

Summary of EMC CS106 Transient, Power Lead Information

CS106 is applicable to submarine and surface ship equipment. It is also applicable to subsystem AC and DC input power leads.

The equipment under test (EUT) can not show any signs of malfunction or degradation of performance. Moreover, the equipment can not deviate from the specified indications when subjected to a test signal with specified voltage levels. This includes tolerances indicated in the individual equipment or subsystem specification.

Specific testing equipment is used to verify the conducted susceptibility of the EUT to withstand transients coupled onto input power leads.

Data presented within this EMC testing procedure specifies detailed and general information. General information may consist of the date, time, location, and test engineer. Specific information includes:

  • Oscilloscope photographs of the calibration waveform.
  • Oscilloscope photographs of the injected waveform for each lead.
  • Data on any susceptibility thresholds that were determined for each power lead.
  • Indications of compliance with the applicable requirements for susceptibility evaluations.

Scope of Unintentional Radiator Conducted Susceptibility Testing

The test equipment used for this EMC testing procedure encompasses a transient generator, capacitor, oscilloscope, resistor, and an isolation transformer. 

The test is set up as follows:

  • The basic set-up for the EUT is maintained;
  • Next, the equipment is calibrated and configured;
  • Then, the oscilloscope is set up to monitor the specified voltage across the resistor;
  • Following the calibration process, the EUT is tested.

After the setup of the equipment is the procedure. This is conducted by carrying out three main steps.

First, the measuring equipment is turned on and allowed sufficient time for stabilization.

Next, calibration is performed. This is done by setting the transient generator to minimum output, increasing the applied signal of the oscilloscope, and recording the setting of the transient generator.

The EUT is turned on and allowed sufficient time for stabilization. While maintaining the required signal level, the transient pulses are applied. Lastly, the information is recorded.

These steps are repeated for each power lead and test condition as required.

Keystone Compliance Provides Expert MIL-STD 461 Testing

Keystone has a full lab of test equipment which permits us to provide short lead times on scheduling. Keystone Compliance can accommodate fixed, mobile and portable devices of all sizes. In addition to conducted susceptibility EMC testing, Keystone has a full scope of expertise including environmental and package testing such as accelerated aging, temperature, and ingress protection.