RTCA DO-160

Section 25.0 Electrostatic Discharge

RTCA DO-160G, Section 25.0

What It Evaluates

Operate the equipment using representative mounting, bonding, grounding, and Section 20 cabling. Use a 150 pF capacitor, 330 Ω resistor, and air-discharge generator calibrated to 15 kV (+10/−0%) in both polarities; connector pins are excluded.

Equipment Categories:

  • Category A: Equipment accessible during normal aircraft operation or maintenance.

When It Applies

Applicability depends on the airborne equipment installation, declared category, aircraft environment, and program requirements.

Likely Procedures

Typical Ranges / Conditioning

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.