RTCA DO-160
Section 22.0 Lightning Induced Transient Susceptibility
RTCA DO-160G, Section 22.0
What It Evaluates
Install and operate the equipment in its representative aircraft configuration on a metallic ground plane of at least 2.5 m². Cable bundles are normally at least 3.3 m long, supported 50 mm above the ground plane, with normal shielding, bonding, loads, and LISNs.
Equipment Categories:
- A/B with Levels 1–5: Pin-injection waveform set and severity.
- C–F or G–K with Levels 1–5: Cable-bundle single-stroke or combined single- and multiple-stroke testing.
- L/M with Levels 1–5: Cable-bundle multiple-burst testing.
- X/Z: Test not performed or alternate waveforms, configurations, or levels used.
When It Applies
Applicability depends on the airborne equipment installation, declared category, aircraft environment, and program requirements.
Likely Procedures
Typical Ranges / Conditioning
This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.