RTCA DO-160

Section 19.0 Induced Signal Susceptibility

RTCA DO-160G, Section 19.0

What It Evaluates

Use representative cable lengths, shielding, twisting, terminations, and connected loads. Frequency scans use at least 30 logarithmic steps per decade with a 10-second dwell, or a continuous sweep no faster than 5 minutes per decade.

Equipment Categories:

  • C, Z, A, B: Descending induced-signal severity levels.
  • C, N, W: Constant, narrow-variable, or wide-variable aircraft power frequency.
  • E or X: Electric-field enclosure testing required or not required.

When It Applies

Applicability depends on the airborne equipment installation, declared category, aircraft environment, and program requirements.

Likely Procedures

Typical Ranges / Conditioning

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.