RTCA DO-160

Section 17.0 Voltage Spike

RTCA DO-160G, Section 17.0

What It Evaluates

Category A uses a 600 V open-circuit spike; Category B uses twice the AC RMS or DC line voltage, or 200 V—whichever is lower. The 50 Ω generator waveform must have a rise time of 2 µs or less and a duration of at least 10 µs.

Equipment Categories:

  • Category A: High protection against voltage-spike damage.
  • Category B: Lower voltage-spike protection is acceptable.

When It Applies

Applicability depends on the airborne equipment installation, declared category, aircraft environment, and program requirements.

Likely Procedures

Typical Ranges / Conditioning

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.