509.7 Salt Fog

MIL-STD-810H Part Two, Method 509.7

What It Evaluates

Use a 5 ±1% sodium-chloride solution at 35 ±2°C, with collected-solution pH between 6.5 and 7.2. Maintain a fallout rate of 1–3 mL/80 cm²/hr with minimal chamber airflow.

When It Applies

Applies when the product lifecycle, platform, storage, transport, deployment, or operating environment includes credible exposure.

Likely Procedures

Procedure selection requires engineering review of the item lifecycle and contract requirements.

Typical Ranges / Conditioning

Severity, duration, and conditions require engineering tailoring; no generic value is assigned by this tool. Conditioning details require review by qualified engineers and applicable contract requirements.

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.