MIL-STD-461 EMC

RE101 Radiated Emissions, Magnetic Field

MIL-STD-461, RE101

What It Evaluates

Measures low-frequency magnetic fields produced by equipment enclosures and electrical cable interfaces.

Applies from 30 Hz–100 kHz, excluding intentional antenna radiation, with compliance measured at 7 cm. Use a 13.3 cm, 36-turn electrostatically shielded loop sensor having 5–10 Ω winding resistance.

When It Applies

Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.

Typical Applicability

Verify the measurement system at 50 kHz using a signal at least 6 dB below the limit and confirm the result within ±3 dB. Operate the equipment and move the loop 7 cm from every face and electrical connector, surveying 30 Hz–1 kHz, 1–10 kHz, and 10–100 kHz, then orient the loop for maximum response and record a full scan at each identified hotspot.

Setup Notes

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.