What It Evaluates
Applies personnel-borne electrostatic discharges to accessible conductive and nonconductive equipment surfaces.
Operate the equipment with the ESD generator grounded to its chassis-ground point. Applicable levels are ±2 kV air, ±4 kV air, ±8 kV contact or air, and ±15 kV air.
When It Applies
Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.
Typical Applicability
Apply five positive and five negative discharges at each selected test point for every applicable level. Contact discharge is applied directly; air discharge approaches the point at no more than 0.3 m/s, with residual charge removed between applications using a 1 MΩ resistor, ionizer, or sufficient waiting time.
Setup Notes
Setup notes and technical limits must be entered from verified source requirements.