MIL-STD-461 EMC

CS118 Personnel Borne Electrostatic Discharge

MIL-STD-461, CS118

What It Evaluates

Applies personnel-borne electrostatic discharges to accessible conductive and nonconductive equipment surfaces.

Operate the equipment with the ESD generator grounded to its chassis-ground point. Applicable levels are ±2 kV air, ±4 kV air, ±8 kV contact or air, and ±15 kV air.

When It Applies

Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.

Typical Applicability

Apply five positive and five negative discharges at each selected test point for every applicable level. Contact discharge is applied directly; air discharge approaches the point at no more than 0.3 m/s, with residual charge removed between applications using a 1 MΩ resistor, ionizer, or sufficient waiting time.

Setup Notes

Setup notes and technical limits must be entered from verified source requirements.

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.