MIL-STD-461 EMC

CS109 Conducted Susceptibility, Structure Current

MIL-STD-461, CS109

What It Evaluates

Injects low-frequency current through equipment structures, cable shields, and mounting interfaces.

Applies from 60 Hz–100 kHz to equipment operating at 100 kHz or below with sensitivity of 1 µV or better; handheld equipment is exempt. Establish a single-point ground, isolate AC power, disconnect safety grounds, and support the equipment on nonconductive surfaces.

When It Applies

Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.

Typical Applicability

Connect the source and 0.5 Ω resistor across diagonal mounting-surface extremes or between cable armor and ground using conductors perpendicular to the surface for at least 50 cm. Operate the equipment and sweep 60 Hz–100 kHz while maintaining at least the applicable current limit and monitoring for susceptibility.

Setup Notes

Setup notes and technical limits must be entered from verified source requirements.

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.