MIL-STD-461 EMC
CS101 Conducted Susceptibility, Power Leads
MIL-STD-461, CS101
What It Evaluates
Injects low-frequency ripple onto power inputs to evaluate equipment immunity to power-system interference.
Test DC equipment from 30 Hz–150 kHz and AC equipment from the second harmonic of its power frequency to 150 kHz. Calibrate through a 0.5 Ω load and inject through a coupling transformer and 10 µF capacitor.
When It Applies
Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.
Typical Applicability
Calibrate the source to the required power limit, which decreases from approximately 80 W at low frequencies to 0.09 W at 150 kHz. Inject the signal onto each applicable power configuration until the voltage or power limit is reached, sweep the complete range, and monitor for malfunction or performance degradation.
Setup Notes
Setup notes and technical limits must be entered from verified source requirements.
This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.