MIL-STD-461 EMC
CE106 Conducted Emissions, Antenna Terminal
MIL-STD-461, CE106
What It Evaluates
Measures harmonics, spurious outputs, and receiver emissions appearing at equipment antenna ports.
Applies from 10 kHz–40 GHz, with start and stop frequencies based on the equipment’s operating range. It does not apply to permanently mounted active antennas, phased arrays, or phasing antennas.
When It Applies
Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.
Typical Applicability
Measure the transmitter fundamental, exclude its occupied bandwidth or ±5%, and scan the remaining range for harmonics and spurious emissions. Receivers and equipment in standby are limited to 34 dBµV; transmitter emissions generally require 80 dB suppression, with second and third harmonics limited to −20 dBm or 80 dB below the fundamental.
Setup Notes
Setup notes and technical limits must be entered from verified source requirements.
This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.