MIL-STD-461 EMC

CE101 Conducted Emissions, Power Leads, 30 Hz to 10 kHz

MIL-STD-461, CE101

What It Evaluates

Measures low-frequency current emissions returning from equipment onto the platform power system.

Applies from 10 kHz–10 MHz to power leads and returns directly connected to the platform power bus. Each lead is stabilized through a 5 µH LISN.

When It Applies

Applicability depends on platform, installation, interfaces, procurement requirements, and the controlling revision.

Typical Applicability

Verify the LISN and measurement path at 10.5 kHz, 100 kHz, 1.95 MHz, and 9.8 MHz using signals at least 6 dB below the applicable limit. Operate the equipment and measure emissions from each power lead through the LISN across the complete frequency range.

Setup Notes

Setup notes and technical limits must be entered from verified source requirements.

This tool provides preliminary planning information only. Final MIL-STD-810H, MIL-STD-461, and RTCA DO-160 requirements must be reviewed and tailored by qualified engineers based on the product, lifecycle, platform, environment, and contract requirements.